Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
 ;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
 ;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
8.5.
Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will start to avoid overcooling. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be risen by 0.5°C at the start of operation and by 0.5°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
Heating Operation When you press the SLEEP Mode, the following movement will start to avoid overheating. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be descented by 2°C at the start of operation and by 3°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
8.6.
Auto Restart Control
� If there is a power failure, operation will be automatically restarted when the power is resumed. It will start with previous operation mode and airflow direction. (Time Delay Safety Control is valid) � Auto Restart Control is not available when Timer or Sleep Mode is set. � This control can be omitted by cutting the jumper wire J2. (Refer Circuit Diagram)
8.7.
Indoor Fan Speed Control
� Auto Fan Speed Control When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. � Manual Fan Speed Control Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.
Fan Speed Cooling Soft Dry Manual Auto Sleep Manual, Auto Sleep Manual Auto Sleep O O O O High Speed �� Low Speed O O O O O O O O O O O O Lo SLo SSLo
O O
Heating
O O Hi
O O Me
O STOP
|
|
 |
> |
|